# BUG # APC USV Error Meldungen bei richtigem Konfig File !!!
Meldung bei Start des APC Dämons debianserver:/# /etc/init.d/apcupsd start /etc/default/apcupsd: line 4: UPSCABLE: command not found ???
/etc/default/apcupsd # Apcupsd-devel internal configuration APCACCESS=/sbin/apcaccess ISCONFIGURED=yes UPSCABLE 940-0024C UPSTYPE smartups DEVICE /dev/ttyS0 LOCKFILE /var/lock UPSCLASS standalone UPSMODE disable
folgende Zeilen in /etc/init.d/apcupsd auskommentieren Code: > #. $CONFIG > #if [ $ISCONFIGURED = no ] > #then > # echo -n "Please check your configuration " > # echo " ISCONFIGURED in /etc/default/apcupsd" > # exit 0 > #fi Dann restarten und geht xD
Test der APC USV !!!
1. mit killall apcupsd den laufenden APC Dämon Prozess killen sonst gibts Fehlermeldungen like -> Setting up the port ... apctest FATAL ERROR in device.c at line 68 Unable to create UPS lock file. apctest FATAL ERROR in device.c at line 68 Unable to create UPS lock file. apctest error termination completed 2. apctest auf der Konsole ausführen und z.B. alle Values mit Auswahl 1 anzeigen looks like -> Now running through apcupsd get_UPS capabilities(). NA indicates that the feature is Not Available UPS Status: 08 Line quality: FF Reason for last transfer to batteries: O Self-Test Status: NO Line Voltage: 233.2 Line Voltage Max: 236.1 Line Voltage Min: 231.8 Output Voltage: 233.2 Batt level percent: 021.0 Batt voltage: 13.77 UPS Load: 000.0 Line freq: 50.00 Runtime left: 0039 UPS Internal temp: NA Dip switch settings: NA Register 1: 00 Register 2: 00 Register 3: 00 Sensitivity: M Wakeup delay: 000 Sleep delay: 180 Low transfer voltage: 208 High transfer voltage: 253 Batt charge for return: 15 Alarm status: L Low battery shutdown level: 02 UPS Name: UPS_IDEN UPS Self test interval: OFF UPS manufacture date: 12/17/99 UPS serial number: NS9951152461 Date battery replaced: 12/17/99 Output voltage when on batteries: 230 Nominal battery voltage: 012 Percent humidity: NA Ambient temperature: NA Firmware revision: 22.4.I Number of external batteries installed: NA Number of bad batteries installed: NA UPS model as defined by UPS: CWI ...